ELECTRICAL REQUIREMENTS

Wire Size

Unit

MUST

Sample Nameplate

120524

COOLING EQUIPMENT

FOLLOWING ITEMS

OUTDOOR GRILLE

INDOOR GRILLE

SAMP

LE

Electrical Rating Tables

4

1

A

5

1

2

1

A

0

2

0

1

A

0

3

All 208/230v chassis must be hard wired with properly sized breaker. See nameplate for specific chassis electrical

Supply voltage

requirements. See figure 9 (Page 12) for unit wiring and wall thermostat wiring. See Electrical Rating Table below for wire siz

Use HACR type breakers to avoid nuisance trips. All field wiring must be done in accordance with NEC and local codes.

NOTICE

ELECTRIC SHOCK HAZARD

WARNING

Turn off electric power before service or instal-

lation. All electrical connnections and wiring

MUST be installed by a qualified electrician and

conform to the National Electrical Code and all

local codes which have jurisdiction. Failure to

do so can result in personal injury and/or death.

ELECTRIC SHOCK HAZARD

Not following the previous WARNING could result in fire or

electrically unsafe conditions which could cause moderate

or serious property damage. Read, understand and follow

the previous warning.

Supply voltage to the unit should be a nominal 208/230 volts. It must be between 197 volts and 253 volts. Supply voltage to

the unit should be checked WITH THE UNIT IN OPERATION. Voltage readings outside the specified range can be expected

to cause operating problems. Their cause MUST be investigated and corrected.

“Use

ONLY time delayed fused disconnect or HACR type circuit breaker as indicated on the unit’s rating plate (see

sample on this page). Proper current protection to the unit is the responsibility of the owner”.