ROUTINe MAINTeNANCe

AIR FILTER

Clean the unit air intake filter at least every 300 to 350 hours of operation. Clean the filters with a mild detergent in

warm water and allow to dry thoroughly before reinstalling.

Units are to be inspected and serviced by qualified service

personnel only. Use proper protection on surrounding

property. Failure to follow this notice could result in

moderate or serious property damage.

Do not use a caustic coil cleaning agent on coils or base

pan. Use a biodegradable cleaning agent and degreaser,

to prevent damage to the coil and/or base pan.

NOTICE

NOTICE

BLOWER WHEEL / HOUSING / CONDENSER FAN / SHROUD

Inspect the indoor blower housing, evaporator blade, condenser fan blade and condenser shroud periodically (yearly or

bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.). Clean the blower housing area and blower wheel with an

antibacterial / antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser

shroud. Use warm or cold water when rinsing these items. Allow all items to dry thoroughly before reinstalling them.

The indoor coil (evaporator coil), the outdoor coil (condenser coil) and base pan should be inspected periodically

(yearly or bi-yearly) and cleaned of all debris (lint, dirt, leaves, paper, etc.). Clean the coils and base pan with a soft

brush and compressed air or vacuum. If using a pressure washer, be careful not to bend the aluminium fin pack. Use

a sweeping up and down motion in the direction of the vertical aluminum fin pack when pressure cleaning coils. Cover

all electrical components to protect them from water or spray. Allow the unit to dry thoroughly before reinstalling it in

the sleeve.

EXCESSIVE WEIGHT HAZARD

WARNING

Use two people to lift or carry the unit, and wear

proper protective clothing.

Failure to do so may result in personal injury.

ELECTRIC SHOCK HAZARD

WARNING

Turn off electric power before inspections,

maintenances, or service.

Extreme care must be used, if it becomes

necessary to work on equipment with power

applied.

Failure to do so could result in serious injury

or death.

ELECTRONIC / ELECTRICAL / MECHANICAL

COILS AND BASE PAN

Periodically (at least yearly or bi-yearly): inspect all control components: electronic, electrical and mechanical, as well

as the power supply. Use proper testing instruments (voltmeter, ohmmeter, ammeter, wattmeter, etc.) to perform elec-

trical tests. Use an air conditioning or refrigeration thermometer to check room, outdoor and coil operating tempera-

tures. Use a sling psychrometer to measure wet bulb temperatures indoors and outdoors.
Inspect the surrounding area (inside and outside) to ensure that the unit’s clearances have not been compromised or

altered.

CUT/SEVER HAZARD

WARNING

Be careful with the sharp edges and corners.

Wear protective clothing and gloves, etc.

Failure to do so could result in serious injury.