REFRIGERANT SYSTEM DIAGNOSIS COOLING

REFRIGERANT SYSTEM DIAGNOSIS HEATING

Low Load Conditions

High Load Conditions

Low Load Conditions

High Load Conditions

Low Air Flow Across

High Air Flow Across

Refrigerant System

Low Air Flow Across

Indoor Coil

Indoor Coil

Restriction

Outdoor Coil

Refrigerant System

Reversing Valve not

Reversing Valve not

Overcharged

Restriction

Fully Seated

Fully Seated

Undercharged

Overcharged

Non-Condensables (air)

Undercharged System

Moisture in System

Defective Compressor

Defective Compressor

LOW SUCTION PRESSURE

HIGH SUCTION PRESSURE

LOW HEAD PRESSURE

HIGH HEAD PRESSURE

LOW SUCTION PRESSURE

HIGH SUCTION PRESSURE

LOW HEAD PRESSURE

HIGH HEAD PRESSURE

PROBLEM

PROBLEM

PROBLEM

PROBLEM

PROBLEM

PROBLEM

PROBLEM

PROBLEM

Low Air Flow Across

Outdoor Ambient Too High

Refrigerant System

Outdoor Ambient Too High

Outdoor Coil

for Operation in Heating

Restriction

For Operation In Heating

Refrigerant System

Reversing Valve not

Reversing Valve not

Low Air Flow Across

Restriction

Fully Seated

Fully Seated

Indoor Coil

Undercharged

Overcharged

Defective Compressor

Undercharged

Overcharged

Moisture in System

Defective Compressor

Non-Condensables (air)

in System

tRoUBLESHootIng CHaRt - CooLIng

tRoUBLESHootIng CHaRt - HEatIng