SLEEVE / DRAIN

Inspect the sleeve and drain system periodically (at least yearly or bi-yearly) and clean of all obstructions and

debris.

Clean both areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and

ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as

needed.

FRONT COVER

Clean the front cover when needed. Use a mild detergent. Wash and rinse with warm water. Allow it to dry

thoroughly before reinstalling it in the chassis.

CONDENSATE DISPOSAL SYSTEM

Part 1: The system’s first stage increases energy efficiency utilizing a factory installed fan that slings the cold

condensate onto the hot outdoor coil.

Part 2: When high outdoor humidity prevents slinger from disposing of all the condensate, the excess condensate

overflows into the condensate drain pan and out of the

3/4”

internal drain connections.

RoUtInE maIntEnanCE (Continued)

Do not drill holes in the bottom of the drain pan or the

underside of the unit. Not following this notice could

result in damage to the unit or condensate water leaking

inappropriately which could cause water damage to

surrounding property.

NOTICE

If Parts 1 and 2 fail for any reason, excess condensate

overflows from a spillway directly into the wall plenum to

the outside of the building.

IF THIS OCCURS, THIS IS

A WARNING THAT THE CHASSIS OR DRAIN NEED

SERVICING.