Selecting a cable type, 2selecting a cable type – FANUC Robotics America GFK-1535A User Manual

Page 34

Advertising
background image

GFK-1535A

Chapter 2 Installation

2-15

2

Selecting a Cable Type

Proper cable selection is critical to successful operation of the system. Each bus in
the system can be any cable type listed in the table below.

Cable #
& Make

NEC

(USA)

Type

Outer

Diameter

Terminating

Resistor*

-10%to+20%

Number of

Conductors/

AWG

Dielectric

Voltage

Rating

Ambient

Temp

Rating

Maximum Length Cable Run,

feet/meters at baud rate

1/2 Watt

153.6s

153.6e

76.8

38.4

(A)9823
(C)4596

(M)M39240

none

CL2

CM

.350in

8.89mm

150 ohms

2 / #22

30v

60

°

C

2000ft

606m

3500ft

1061m

4500ft

1364m

7500ft

2283m

(B)89182

CL2P

.322in

8.18mm

150 ohms

2 / #22

150v

200

°

C

2000ft

606m

3500ft

1061m

4500ft

1364m

7500ft

2283m

(B)9841

(M)M3993

CM

CL2

.270in

6.86mm

120 ohms

2 / #24

30v

80

°

C

1000ft

303m

1500ft

455m

2500ft

758m

3500ft

1061m

(A)9818C

(B)9207

(M)M4270

CL2

CM
CM

.330in

8.38mm

100 ohms

2 / #20

300v

80

°

C

1500ft

455m

2500ft

758m

3500ft

1061m

6000ft

1818m

(A)9109

(B)89207

(C)4798

(M)M44270

CL2P

CM

*

CMP

.282in

7.16mm

100 ohms

2 / #20

150v

200

°

C

1500ft

455m

2500ft

758m

3500ft

1061m

6000ft

1818m

(A)9818D

(B)9815

none

*

.330in

8.38mm

100 ohms

2 / #20

1500ft

455m

2500ft

758m

3500ft

1061m

6000ft

1818m

(O)911264

**

none

.260in

6.60 mm

100 ohms

2 / #22 flexing

250V

80

°

C

1500ft

455m

2000ft

606m

3000ft90

9m

4500ft

1364m

(E)532185

BBDN

CM

approx

.50in

(12.7mm)

100 ohms

4 pairs #24

(solid)

>150V

80

°

C

1500ft

455m

2000ft

606m

3000ft

909m

4500ft

1364m

(A)9818
(B)9855

(M)M4230

*

CM
CM

.315in

8.00mm

100 ohms

4 (two pair)

#22

150v

60

°

C

1200ft

364m

1700ft

516m

3000ft

909m

4500ft

1364m

(A)9110

(B)89696
(B)89855

none
CMP
CMP

.274in

6.96mm

100 ohms

4 (two pair)

#22

150v

200

°

C

1200ft

364m

1700ft

516m

3000ft

909m

4500ft

1364m

(A)9814C)

(B)9463

(M)M4154

none

CM

CL2

.243in

6.17mm

75 ohms

2 / #20

150v

60

°

C

800ft

242m

1500ft

455m

2500ft

758m

3500ft

1061m

(A)5902C

(B)9302

(M)M17002

none

CM
CM

.244in

6.20mm

75 ohms

4 (two pair)

#22

300v

80

°

C

200ft

60m

500ft

152m

1200ft

333m

2500ft

758m

Notes: A = Alpha, B = Belden, C = Consolidated, E = Essex, M = Manhattan, O = Olflex

= Limited to 16 taps at 38.4 Kbaud

* = not known

**= Suitable for applications requiring high flexibility, continuous flex or vibration.

Advertising