Applications

Using the Dual Display

4

4-3

Table 4-1. Sample Dual Display Applications

Primary Display

Secondary Display

Applications

Volts DC

Volts AC

•

Monitor dc level and ac ripple of power supply
Troubleshoot amplifier circuits

Volts DC

Current DC

•

Check power supply load regulation

•

Monitor UUT current draw and circuit voltages

•

Monitor loop current and voltage drop across
transmitter

Volts DC

Current AC

•

Line and load regulation tests

•

dc/ac or ac/dc converters

Volts AC

Current DC

•

Line and load regulation tests

•

dc/ac or ac/dc converters

Volts AC

Current AC

•

Line and load regulation tests

•

Transformer (magnetic circuit) saturation

Volts AC

Frequency

•

Measure ac amplitude and frequency for line
voltage and ac signal analysis

•

Measure frequency response of an amplifier

•

Adjust ac motor control

•

Read noise in telecommunication applications

•

Adjust portable power generator to optimize
power output

•

Set frequency compensation for a network

dB (in Volts dc)

Frequency

•

Use in "print-only" mode (see "RS-232 Print-
Only Mode" in Chapter 5) for quick Bode plots
(frequency vs. amplitude)

•

Test frequency response

Current DC

Current AC

•

Measure ripple and dc current draw of switching
power supply

•

Measure current dissipation in protective fuse
resistors used in power supplies

•

Measure ripple and noise on a line

MN MX

Actual Value

•

Show the minimum or maximum value recorded
and the present measurement

REL

Actual Value

•

Show actual measurement and the difference
between this value and the relative base.

REL

Resistance

•

Select and sort resistors. (See also "Using the
Compare Function" in Chapter 3.)

HOLD

Actual Value

•

Show actual measurement while holding a
previous, stable measurement on the primary
display

Advertising