RS-232 Print-Only Mode

The print-only mode is intended to be used primarily in those cases where you want to
send measurements taken by the meter to a printer or terminal automatically.

While the meter will respond to remote commands during "print-only" operations, we
recommend first setting the meter’s echo mode to "OFF" (see above). This will prevent
mixing echoed command characters and incoming data.

In the print-only mode, the meter sends every Nth reading shown on the primary and/ or
secondary displays out the RS-232 port. The print rate (N) is selected by the user from
the available values for N. provided in Table 5-2. The duration between output is
determined by the reading rate of the meter (slow (2.5), medium (5.0), or fast (13.5) and
the print-only rate. The output is formatted as one measurement per line from the primary
display or two measurements per line from the primary and secondary display.

Table 5-2. Approximate Print Rates in RS-232 Print-Only Mode

Seconds Between Output

Minutes Between Output

Hours Between Output

Rate (N)

Slow

Medium

Fast

Slow

Medium

Fast

Slow

Medium

Fast

1

2

5

10

20

50

100

200

500

1000

2000

5000

10000

20000

50000

0.4

0.8

2.0

4.0

8.0

20.0

40.0

80.0

200.0

400.0

800.0

2000.0

4000.0

8000.0

20000.0

0.2

0.4

1.0

2.0

4.0

10.0

20.0

40.0

100.0

200.0

400.0

1000.0

2000.0

4000.0

10000.0

0.07

0.1

0.3

0.6

1.0

3.0

6.0

11.0

25.0

50.0

100.0

250.0

500.0

1000.0

2500.0

0.1

0.1

0.3

0.7

1.3

3.3

6.7

12.3

33.3

66.7

133.3

333.3

0.1

0.2

0.3

0.7

1.7

3.3

6.7

16.7

33.3

66.7

166.7

0.1

0.2

0.4

0.8

1.7

4.2

8.3

16.7

41.7

0.1

0.1

0.2

0.6

1.1

2.2

5.6

0.1

0.1

0.3

0.6

1.1

2.8

0.1

0.1

0.3

0.7

A 240 milliseconds asynchronous pause in the data output of occurs every three seconds.

Perform the following procedure to select the print-only mode and set a printing rate (N):

1.

Press in the POWER button on the front panel to turn the meter on.

2.

Press

S, then press J (ADDR).

If the RS-232 interface is selected, "PRINT" is shown in the secondary display and
the list editor is invoked on the print rate list.

3.

Press

U or T to scroll to one of the print rates shown in Table 5-2, then press

E to select that rate. A print rate of "0" disables the print-only mode.