1 installing the fryer (cont.) – Frymaster FDP65 User Manual

Page 15

Advertising
background image

FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3-2

3.1 Installing the Fryer (cont.)


3. Connect red/white or red/yellow wires (Figure 4,

left) between fryer sections being assembled
(Figure 4, right, arrow). Oil-return will not
operate properly if these wires are not connected.

NOTE: On systems shipped in three or more
sections, additional wiring between cabinets
will exist. Ensure all wires are connected
before completing cabinet assembly.

4. Remove the lower back panel-strips on fryers

being assembled to gain access to the oil return
and rinse-line connections (Figure 5, arrows).
Back removal may not be required on some
systems.

5. Slowly push the two cabinets together. Ensure

the drainpipe and slip-nut are aligned with the
drain-tee on the opposite fryer section. Ensure
the oil-return and rinse-hose connections (where
applicable) on each fryer section are aligned.
Ensure oil-return switch wires between cabinet
sections are not pinched when the cabinets are
brought together. Pull excess wire through the
opposite fryer side as the cabinets are brought
together. Secure excess wire inside cabinet with
a wire tie.

6.

With the cabinets together, insert the drainpipe
into the opposite fryer drain-tee and position it
evenly between the fryers being connected.

Connect the oil-return and rinse-lines by
accessing the oil return union through the lower
fryer-back openings. Connect all fittings, but do
not tighten at this time.

7. Align the cabinet connection holes, front and

back (Figure 6, arrow). Connection hardware is
included in the accessories pack. Insert bolts and
install nuts, but do not tighten. If holes do not
align, use a 3/16" drill-bit and drill through the
misaligned hole.

8. Install the frypot joiner strip between cabinet

sections (Figure 7; also see factory-installed
strips on two-battery cabinet sections).




Figure 5. Oil return and rinse-line (where
applicable) connections.

Figure 4. Oil return wires between sections
must be connected for oil-return operation.

Figure 6. Cabinet connection locations
inside cabinet sections (front shown).

Figure 7. Install joiner strip(s) after fryers
are connected.