Frymaster FDP65 User Manual

Page 37

Advertising
background image

FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 5: FILTRATION OPERATION

5-10

5.4.1 Filter Operation (cont.)


11. After all shortening is pumped back into the

frypot, bubbles will form, indicating air in the
oil return lines. Allow the shortening to
bubble for 15-30 seconds to ensure all
shortening is cleared from the return lines.
An audible alarm will sound, indicating that
the frypot is full. Push the yellow handle to
close the oil return valve and deactivate the
filter pump.






12. If the shortening level is low, add fresh

shortening until the level is at the top OIL
LEVEL line (the shortening is at operating
temperature).










13. Do not allow crumbs to accumulate in the

crumb tray. The crumb tray MUST be
emptied into a fireproof container at the end
of frying operations EACH day.














Allow the oil to bubble for 15-30 seconds to
ensure evacuation of all oil in the return lines.

Add fresh shortening until the level is at the top
OIL LEVEL line. DO NOT OVERFILL THE
FRYPOT.

Empty the filter pan crumb tray into a fire-proof
container at the end of frying operations each day.
DO NOT ALLOW CRUMBS TO ACCUMULATE IN
TRAY.

Advertising