FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 5: FILTRATION OPERATION

5-8

5.4.1 Filter Operation (cont.)

4. When all the oil has drained from the frypot,

connect the hose-wand assembly to the
disconnect valve in the fryer cabinet. DO
NOT ACTIVATE FILTER PUMP UNTIL
THE HOSE HAS BEEN PROPERLY
CONNECTED. Ensure the hose-disconnect
is properly connected before proceeding.

Remove the frypot wire rack prior to rinsing
frypot.









5. Place the hose wand into the frypot being

filtered and activate the rinse valve by turning
the blue handle to "WAND" (where
applicable), or by pressing the manual bypass
switch (systems without oil disposal system).
The filter pump will activate and oil will start
flowing through the rinse hose.





6. Hold the wand inside the frypot at a 45-

degree angle while the rinse valve is opened.


7. Use the wand to rinse debris from the frypot

for approximately 3 minutes. At the end of 3
minutes, the computer display will alternate
from

OPEN DRAIN to the timed

countdown cycle (10 minutes). Turn the blue
handle or the manual bypass switch to "OFF",
and then close the drain valve (red handle).
Disconnect and drain the hose of all
shortening or oil. Hang hose upright to
ensure no shortening remains in hose.












Use the wand to rinse debris from the frypot into
the filter pan. Maintain a firm grip on the wand
handle at all times.

After the hose wand end is properly positioned in
the frypot, activate the filter pump by turning the
blue handle to "WAND" (where applicable).

Hose/wand disconnect properly connected to
disconnect valve in fryer cabinet (orientation of
disconnect may vary according to system).