FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3-9

3.3.2 Gas Conversion Procedures (cont.)


Contact factory with the following information when performing conversions:


• Fryer Serial Number

• Fryer Model Number
• Gas Type

• Operating Altitude

Conversions can only be executed by qualified, factory-authorized personnel
.

Pressure flow adjustment

(remove cover screw to access)

ON/OFF Gas-Cock Knob

Pilot gas supply connection.

Regulator Vent

Pilot pressure adjustment

(remove cover screw to access)


3.4 Electrical Connections

The fryer when installed must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).

DANGER

This fryer is equipped with three-prong (grounding) plugs for protection against

electrical shock and must be plugged directly into a properly grounded, three-prong

receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING

PRONGS ON THESE PLUGS!


The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a
120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system
(International/CE). Do not cut or remove the ground prong from any of the power cord plugs. Do
not attempt to use the fryer during a power outage.

DANGER

This appliance requires electrical power for operation. Place the gas control valve in

the OFF position in case of a prolonged power outage. Do not attempt to operate

this appliance during a power outage.

Typical gas valve