FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3-7

3.2 Gas Connections (cont.)

I. Flexible Couplings, Connectors and Casters:

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the

installer must use a heavy-duty AGA design-certified commercial flexible connector of
at least 1" NPT (with suitable strain reliefs), in compliance with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69-(latest edition) and Addenda
Z21.69a-(latest edition). Quick disconnect devices must comply with the Standard for
Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-(latest edition).

WARNING

Do not attach accessories to this fryer unless fryer is secured from tipping.

Personal injury may result.

2. The fryer must be restrained by means independent of the flexible coupling or

connector in order to limit the movement of the fryer. Clips are located on the back
panel of the fryer for the attachment of restraints.

3. If disconnection of the restraint is necessary, this restraint must be reconnected after the

fryer has been returned to its originally installed position.

J. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.

3.3 Adjustments/Adaptation To Different Gases

A. Proper operation of Frymaster/Dean gas fryers requires operator to inspect the following

adjustments in terms of:

1. Gas inputs and pressures.

2. Voltage and polarities of electrical power supplies.

B. Frymaster/Dean gas fryers are manufactured to use the type of gas and pressure specified on

the rating plate. When changing to a different gas, adaptation must be performed by
qualified personnel.
Failure to use qualified personnel will void the Frymaster/Dean
warranty.