Frymaster FDP65 User Manual

Page 21

Advertising
background image

FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3-8

3.3.1 Specifications

3.3.1.1 Adjustments to Different Gas Types

Gas Adjustments

Gas Type

Natural LP

Manifold Pressure†

4" W.C.*/10 mbar*

11" W.C.*/27.5 mbar*

Orifice Diameter

Model Specific

Model Specific

Burner Marking

None None

Pilot Marking

26N (P/N 810-0811)

16LP (P/N 810-2400)

* Gas pressure may vary per fryer model and altitude. Check the rating plate for specific

gas pressures.

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.

† For controls and adjustments, please refer to the "gas valve" illustration on page 3-9. (Pilot Flame

Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved.)



3.3.2 Gas Conversion Procedures

DANGER

This appliance was configured at the factory for a specific type of gas. Converting

from one gas type to another requires the installation of specific gas-conversion

components.

Switching to a different type of gas without installing the proper conversion

components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A

GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.6 of this manual.