2-4

7. Using the terminal opener provided, connect cores (except coaxial cable) to their appropriate

locations on TB801 on the TB Board. Refer to the interconnection diagram for wiring details.

8. Connect the coaxial cable to TB802, referring to the right-hand illustration below..

How to wire WAGO connector

9. Attach crimp-on lug (FV5.5-4) to the shield of the signal cable and fasten it with the screw at

the location specified in the illustration on the preceding page.

10.Process unused cores as follows:

a) Slip shrink tubing onto cores and heat.
b) Bind unused cores with cable tie.

11.Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland

cap. (The gland cap may be discarded.)

12.Fabricate the HV cable as shown below.

How to fabricate HV cable TYPCY-1.5

Fastening coaxial cable

NOTICE

Procedure
1. Twist core.
2. Insert terminal opener as shown and
push down.
3. Insert core into hole.
4. Release terminal opener.
5. Pull wire to confirm that it is firmly in
place.

Terminal opener

Wiring WAGO connector

WAGO connector

Wire

Twist

Push down.

Fasten BARE conductor. Do not use
crimp-on lug, to prevent increased
contact resistance.

Fasten shield
by clamp.

Fasten conductor with screw.

Taping

20 mm

5 mm

Sheath

Armor

Vinyl
sheath

L

Conductor

S = 1.50 mm

2

φ

= 1.56 mm

Armor

Sheath

SECTIONAL VIEW

6

L: 300 mm (red)
L: 370 mm (black, white)

Advertising