17 power supply unit – Furuno FAR2167DS-BB User Manual

Page 40

Advertising
background image

2-17

Power supply unit

Refer to the illustration and table below to add (or remove) jumper connector P8 from the TX-HV
Board (03P9350) and change fuse.

After completing jumper and fuse arrangements, adjust the overvoltage detection circuit, using a
variable transformer.

Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring
to the illustration below. (VH6 connector housing is to be plugged into J8.)

Power

Fuse

Jumper connector P8

100 VAC

5A

Required

220 VAC

3A

Unnecessary

Fuse

TX-HV Board

Unfasten four screws and remove
cover for TX-HV Board.

R21

CR23

P8/J8

Jumper connector
(VH6P)

6 5 4 3 2 1