Furuno FAR2167DS-BB User Manual

Page 34

Advertising
background image

2-11

Cable fabrication for the cables connected to the 03P9342 board

Signal cable RW-9600 (Between antenna unit and processor unit)

Power cable TPYC-1.5

Cables for optional equipment (use TTYCS-1 or TTYCS-4, or equivalent)

Shield

Armor

Fasten cable clamp here.

Vinyl tape

Expose cores, and then
wind shield around armor.

Vinyl sheath

Coaxial cable

6

60

450

5

Conductor

5 9

Coaxial cable

14

Fold back shield.

L

Armor

L: According to location

of connector.

6

60: Peel paint

60: Peel paint.

L

5

Shield

Armor

Fasten cable clamp here.

Vinyl tape

Expose cores, and then
wind shield around armor.

L= Depends on equipment

connected. Measure at
processor unit.

6

Conductor

S = 0.75 mm

φ

= 1.11 mm

2

TTYCS-1

Armor

Shield

Sheath

φ

=

10.1 mm

Conductor

S = 0.75 mm

φ

= 1.11 mm

2

TTYCS-4

Armor

Shield

Sheath

φ

= 16.3

mm

Advertising