2.6 Changing AC Power Specification

To change AC power specification from 100 VAC to 220 VAC and vice versa, change fuse and
jumper wire setting, following the instructions in this section.

Processor unit

As directed in the table below, add or remove jumper connector P108 from the PWR board
03P9339 and change the fuse in the processor unit according to ship's mains. Then, adjust the
overvoltage detection circuit, the procedure for which is shown on the next page.

Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring
to the illustration on the next page. (VH8 connector housing is to be plugged into J108.)

Processor unit, inside view

Power supply

Fuse

Jumper connector P108

100 VAC

10A

Necessary

220 VAC

5A

Unnecessary

Cover of PWR board

Fuse

Upper part of processor unit
(SPU assembly omitted)

PWR board