Chapter 6

Storage Devices Replacement

6-9

6.1.9

Accessing the Hard Disk Drive Backplane of the
M5000 Server

Caution –

There is an electrical hazard if the power cords are not disconnected. All

power cords must be disconnected to completely remove power from the server.

Caution –

Use proper ESD grounding techniques when handling components. See

Section 1.1, “Safety Precautions” on page 1-1

.

1. Power off the server.

This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See

Section 4.4.1,

“Powering the Server Off Using Software” on page 4-12

.

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When drawing out the M4000/M5000 Server to the front, release the cable tie

holding the PCI cables on the rear of the server.

2. Remove the top cover.

This step includes deploying the rack’s antitilt features (if applicable), sliding the
server out of the equipment rack, and removing the top cover. See

Section 5.2.1,

“Removing the Top Cover” on page 5-5

.

Caution –

The motherboard unit is heavy. Two people are recommended to lift the

unit. If the unit is too heavy the memory boards can be removed prior to lifting the
unit.

3. Remove the motherboard unit.

This step includes removing the CPU modules and filler panels, removing the
busbar screws, and removing the motherboard cradle. See

Section 13.1.6,

“Removing the M5000 Server Motherboard Unit” on page 13-8

.