3 installing the 60-mm fan module, 4 securing the server, Installing the 60-mm fan module – FUJITSU M5000 User Manual

Page 170: Securing the server, Section 10.1.3, “installing the

Advertising
background image

10-6

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

10.1.3

Installing the 60-mm Fan Module

Caution –

Do not force the fan into the slot. Doing so can cause damage to the fan

and server.

1. Align the fan module (LED on left) and slide the fan into the slot.

A fan module placed backwards into the slot will stop halfway to prevent damage
to the connectors. If the fan does not slide in easily, remove it, and rotate the fan
180 degrees and then try again.

2. Push down with two fingers to seat the fan module.

10.1.4

Securing the Server

Slide the server into the equipment rack and secure the stabilizer bar.

See

Section 5.1.2, “Sliding the Server Into the Equipment Rack” on page 5-4

.