FUJITSU M5000 User Manual

Page 112

Advertising
background image

6-20

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Note –

If the Oracle Solaris automatic booting is set, use the sendbreak -d

domain_id command after the display console banner is displayed but before the
system starts booting the operating system to get the ok prompt.

3. Confirm the hardware.

This step includes running programs to be certain all components are mounted
again and then booting the operating system.

Refer to

Section 4.3.2, “Verifying Hardware Operation” on page 4-9

for more

information.

6.2.10

Accessing the CD-RW/DVD-RW Drive Backplane
of the M5000 Server

Caution –

There is an electrical hazard if the power cords are not disconnected. All

power cords must be disconnected to completely remove power from the server.

Caution –

Use proper ESD grounding techniques when handling components. See

Section 1.1, “Safety Precautions” on page 1-1

.

1. Power off the server.

This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See

Section 4.4.1,

“Powering the Server Off Using Software” on page 4-12

.

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When drawing out the M4000/M5000 server to the front, release the cable tie

holding the PCI cables on the rear of the server.

2. Remove the top cover.

This step includes deploying the rack’s antitilt features (if applicable), sliding the
server out of the equipment rack, and removing the top cover. See

Section 5.2.1,

“Removing the Top Cover” on page 5-5

.

Advertising
This manual is related to the following products: