Chapter 12

CPU Module Replacement

12-9

Caution –

After installing the CPU module, you must reconnect the power cable to

the power supply.

9. Log in to the XSCF again, using an account with platadm or fieldeng

privileges.

10. Perform an initial diagnosis of the newly installed CPU module.

The following example shows a test after adding PSB#01 to a SPARC Enterprise
M5000 server:

11. Confirm that the installed CPU module is recognized by the server and that the

error indicator asterisk (*) is not displayed.

12. Confirm that no error has occurred.

13. Change the key position on the operator panel from Service to Locked.

14. Power on the existing domains.

15. Set the following for the added CPU module:

Set up XSB for the added CPU module.

Set up the domain.

XSCF> testsb 01

XSCF> testsb 01

Initial diagnosis is about to start. Continue? [y|n] : y

Initial diagnosis is executing.

Initial diagnosis has completed.

XSB Test Fault

---- ------- --------

01 Passed Normal

XSCF> showhardconf -M

XSCF> showlogs error -v

XSCF> showstatus

XSCF> poweron -a