SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

The state displayed by LED combination is described in

TABLE 2-4

.

TABLE 2-4

State Display by LED Combination (Operator Panel)

LED

Description of the state

POWER

XSCF
STANDBY

CHECK

Off

Off

Off

The circuit breaker is switched off.

Off

Off

On

The circuit breaker is switched on.

Off

Blinking

Off

The XSCF is being initialized.

Off

Blinking

On

An error occurred in the XSCF.

Off

On

Off

The XSCF is on standby.
The system is waiting for power-on of the air
conditioning system.

On

On

Off

Warm-up standby processing is in progress
(power-on is delayed).
The power-on sequence is in progress.
The system is in operation.

Blinking

On

Off