C.7 extended system control facility unit, Extended system control facility unit – FUJITSU M5000 User Manual

Page 275

Advertising
background image

Appendix C

FRU List

C-9

Refer to

Section 10.1, “Fan Module Replacement” on page 10-1

for replacement

procedures.

C.7

eXtended System Control Facility Unit

The eXtended System Control facility unit (XSCFU or XSCF unit) contains the service
processor that operates and administrates the servers. It diagnoses and starts the
entire system, configures domains, offers dynamic reconfiguration, as well as detects
and notifies various failures.

The XSCF unit uses the eXtended System Control Facility (XSCF) software to provide
the following functions:

Controls and monitors the main unit hardware

Monitors the Oracle Solaris OS, power-on self-test (POST), and the OpenBoot
PROM

Controls and manages the interface for the system administrator (such as a
terminal console)

Administers device information

Messages various events remotely

Interlocks power due to remote cabinet interface (RCI)

Note –

To use RCI, a SPARC Enterprise server or a device with an RCI port is

required.

Both midrange servers have one XSCF unit, which is serviced from the rear of the
system. To replace it, you must power off the server.

Refer to

Section 9.1, “XSCF Unit Replacement” on page 9-1

for replacement

procedures.

Hot replacement
capability

Yes

Yes

Cold replacement
capability

Yes

Yes

Redundant cooling

2 172-mm fans (1 + 1 redundant)
2 60-mm fans (1+ 1 redundant)

4 172-mm fans (2 + 2 redundant)

TABLE C-6

Fan Module Features (Continued)

M4000 Server

M5000 Server