6-10

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

6.1.10

Removing the Hard Disk Drive Backplane of the
M5000 Server

Note –

The fan units and fan cage can be removed for increased visibility of the hard

disk drive backplane if necessary.

1. Remove the hard disk drive and place it on the ESD mat.

See

Section 6.1.2, “Removing the Hard Disk Drive” on page 6-4

.

2. Disconnect the power cable (p3) from the rear of the hard disk drive backplane.

3. Disconnect the blue serial cable from the hard disk drive backplane.

4. Loosen the captive screw and lift the hard disk drive backplane from the guide

pins and place the backplane on the ESD mat.

6.1.11

Installing the Hard Disk Drive Backplane of the
M5000 Server

1. Place the hard disk drive backplane on the guide pins.

2. Tighten the captive screw that holds the rear of the hard disk drive backplane in

place.

3. Connect the power cable (p3) to the rear of the hard disk drive backplane.

4. Connect the blue serial cable to the hard disk drive backplane.

Caution –

Do not force any components into server slots. Doing so can cause damage

to the component and server.

5. Install the hard drive.

See

Section 6.1.3, “Installing the Hard Disk Drive” on page 6-5

.