3 i/o unit replacement, 1 accessing the i/o unit, 2 removing the i/o unit – FUJITSU M5000 User Manual

Page 142: I/o unit replacement, Accessing the i/o unit, Removing the i/o unit

Advertising
background image

8-10

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

8.3

I/O Unit Replacement

The I/O units are cold replacement components.

8.3.1

Accessing the I/O Unit

Caution –

There is an electrical hazard if the power cords are not disconnected. All

power cords must be disconnected to completely remove power from the server.

Power off the server.

This step includes turning the key switch to the Service position, confirming that the
POWER LED is off, and disconnecting power cables. See

Section 4.4.1, “Powering the

Server Off Using Software” on page 4-12

.

8.3.2

Removing the I/O Unit

Caution –

Use proper ESD grounding techniques when handling components. See

Section 1.1, “Safety Precautions” on page 1-1

.

1. Disconnect and label all the cables that connect to the I/O unit.

2. Remove the cassettes from the I/O unit.

See

Section 8.1.2, “Removing the PCI Cassette” on page 8-5

.

3. Disconnect the cabinet end of the cable management arm.