9 accessing the 60-mm fan backplane, Accessing the 60-mm fan backplane – FUJITSU M5000 User Manual

Page 174

Advertising
background image

10-10

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

10.1.9

Accessing the 60-mm Fan Backplane

Caution –

There is an electrical hazard if the power cords are not disconnected. All

power cords must be disconnected to completely remove power from the server.

1. Power off the server.

This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See

Section 4.4.1,

“Powering the Server Off Using Software” on page 4-12

.

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When drawing out the M4000/M5000 Server to the front, release the cable tie

holding the PCI cables on the rear of the server.

2. Remove the fan cover.

This step includes deploying the rack’s antitilt features (if applicable), sliding the
server out of the equipment rack, removing the 60-mm fan units, and removing
the fan cover. See

Section 5.3.1, “Removing the Fan Cover” on page 5-8

.

Caution –

Use proper ESD grounding techniques when handling components. See

Section 1.1, “Safety Precautions” on page 1-1

.

3. Remove the CD-RW/DVD-RW drive backplane.

This step includes removing the CD-RW/DVD-RW Drive Unit and the
CD-RW/DVD-RW drive backplane. See

Section 6.2.7, “Removing the

CD-RW/DVD-RW Drive Backplane of the M4000 Server” on page 6-18

.