SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

There are two fans in each power supply unit.

The SPARC Enterprise M5000 server has a I/O backplane/power backplane/busbar
unit, located near the center of the lower half of the system, which provides these
functions:

Power conductor to the power supply backplane, fan backplane, power supply
backplane, and motherboard unit

Connectivity between the various backplanes and the motherboard with FRUs and
system components

Refer to

Section 7.1, “Power Supply Unit Replacement” on page 7-1

for replacement

procedures.

C.6

FAN Module

The fans in the midrange servers move air currents into and out of the server. If one
fan fails, the eXtended System Control Facility (XSCF) detects the failure and uses the
redundant fan(s).

Both servers use 172-mm fans (FAN_A) as the primary cooling

system. The 60 mm fans (FAN_B) in the M4000 server are used for additional cooling.

TABLE C-6

describes the fan features.

Volt ampere

1,763 VA

3,406 VA

Power draw (maximum)

1,692W (2 power cords)

3,270W (4 power cords)

Heat

5,774 BTUs/hr (6,091 kJ/hr)

11,160 BTUs/hr (11,772 kJ/hr)

TABLE C-6

Fan Module Features

M4000 Server

M5000 Server

Number of fans

4 fans
• 2 172-mm fans
• 2 60-mm fans

4 172-mm fans

Fan location

172-mm fans—Top of system near
the front
60-mm fans—Top of system
Above the power supply units

Top of system near the front

Active replacement
capability

Yes

Yes

TABLE C-5

Power Supply Features (Continued)

M4000 Server

M5000 Server