F.1 m4000 and m5000 servers air filter, F.1.1 command operations procedures, M4000 and m5000 servers air filter – FUJITSU M5000 User Manual

Page 290: F.1.1, Command operations procedures

Advertising
background image

F-2

SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

F.1

M4000 and M5000 Servers Air Filter

The air filter is held in place on the front of the server with hook and loop tape. The
tape has a sticky backing to it and one set of tape strips is already attached to the
filters. The mating hook and loop tape is attached to the filters tape by the hooks and
loops. The sticky side of this tape still has it’s protective tape covering the sticky side.

The installation process overview is:

Power the Domains off

Perform the Command Operations

Install the Air Filter

Reset the XSCF

Power the Domains on

F.1.1

Command Operations Procedures

Before physically installing the air filters, the server must be made ready to deal with
the new air flow.

1. Login to XSCF.

2. Use the showaltitude(8) command to check that the air filter is not currently

being mounted.

3. Turn off power to all domains.

4. Install the air filter. Proceed to

Section F.2, “Air Filter Installation for the M4000

Server” on page F-3

or

Section F.3, “Air Filter Installation for the M5000 Server” on

page F-9

.

5. Use the setaltitude(8) command to set the air filter installation.

XSCF> showaltitude

1000m

XSCF> setaltitude -s filter=installed

1000m

Filter is installed.

Advertising