2 removing and replacing a fru, 3 adding a fru into a domain, Removing and replacing a fru – FUJITSU M5000 User Manual

Page 69: Adding a fru into a domain

Advertising
background image

Chapter 4

FRU Replacement Preparation

4-5

Caution –

If you use the PCI Hot Plug (PHP) function on the servers with Oracle

Solaris 10 9/10, or 142909-17 or later, enable the hotplug service as follows:
#

svcadm enable hotplug

2. Type the cfgadm command to disconnect the component from the domain:

Note –

For a PCI cassette, type the cfgadm -c disconnect command to

disconnect the component from the domain.

The Ap_Id is shown in the output of cfgadm. iou#0-pci#0 for example.

3. Type the cfgadm command to confirm the component is now disconnected.

4.2.2

Removing and Replacing a FRU

Once the FRU has been removed from the domain, see

Section 4.3.1, “Removing and

Replacing a FRU” on page 4-7

4.2.3

Adding a FRU Into a Domain

1. From the Oracle Solaris prompt, type the cfgadm command to connect the

component to the domain.

The Ap_Id is shown in the output of cfgadm. iou#0-pci#0 for example.

# cfgadm -c unconfigure

Ap_Id

# cfgadm -a

Ap_Id

Type

Receptacle

Occupant

Condition

iou#0-pci#0

etherne/hp

disconnected unconfigured

unknown

iou#0-pci#1

fibre/hp

connected

configured

ok

iou#0-pci#2

pci-pci/hp

connected

configured

ok

# cfgadm -c configure