1 connecting a ups unit, Connecting a ups unit – FUJITSU SPARC M4000/M5000 User Manual

Page 27

Advertising
background image

Chapter 3

Installing the Server

3-3

3.2.1

Connecting a UPS Unit

An uninterruptible power supply (UPS) unit is used to provide a stable supply of
power to the system in the event of a power failure or an extensive power
interruption. A UPS with an UPC interface can be connected to the UPC ports on the
eXtended System Control facility unit (XSCFU or XSCF Unit) (

FIGURE 3-2

) so that

emergency shutdown processing can be executed.

When using a single power feed, connect the UPC cable to UPC#0. When using a
dual-power feed, connect the UPC cables to UPC#0 and UPC#1 (

FIGURE 3-1

).

Note –

UPC#1 cannot be used when using single power feed. Refer to the SPARC

Enterprise M4000/M5000 Servers Service Manual for the interface specifications of the
UPC port.