1 connecting the console, Connecting the console – FUJITSU SPARC M4000/M5000 User Manual

Page 31

Advertising
background image

Chapter 3

Installing the Server

3-7

See

Section A.1, “M4000 Server Views” on page A-1

for the location of the XSCF Unit

on the SPARC Enterprise M4000 server.

3.3.1

Connecting the Console

This section explains how to physically connect and configure the console.

1. Connect the administrative console to the serial port using the serial cable that

shipped with the server.

2. Configure the settings on the administrative console.

The console should have the following settings:

Baud rate: 9600 bps

Data length: 8 bit

Parity: None

Stop: 1 bit

Flow control: None

Delay: Except for 0

3. Set the key on the operator panel to the Service position.

The Service position is indicated by an icon that looks like a wrench, the Locked
position is indicated by an icon that looks like a lock (

FIGURE 3-3

).

5

LAN 0 (Ethernet#0)

6

UPC#1

7

UPC#0

Location Number

Component