SPARC Enterprise M4000/M5000 Servers Installation Guide • December 2010

2. Type the showhardconf command with the -u option from the XSCF Shell.

See the

Section B.2.1, “Using the showhardconf Command” on page B-2

for details.

3. Use the console command to go to the ok prompt.

XSCF> showhardconf -u

SPARC Enterprise M5000; Memory_Size:64 GB;

+-----------------------------------+------------+

| FRU | Quantity |

+-----------------------------------+------------+

| MBU_B | 1 |

| CPUM | 4 |

| Freq:2.530 GHz; | ( 8) |

| MEMB | 8 |

| MEM | 64 |

| Type:1A; Size:1 GB; | ( 64) |

| DDC_A | 4 |

| DDC_B | 2 |

| IOU | 2 |

| DDC_A | 2 |

| DDCR | 2 |

| DDC_B | 2 |

| XSCFU | 1 |

| OPNL | 1 |

| PSU | 4 |

| FANBP_C | 1 |

| FAN_A | 4 |

+-----------------------------------+------------+

XSCF> console -d 0