background image

3-8

SPARC Enterprise M4000/M5000 Servers Installation Guide • December 2010

FIGURE 3-3

Operator Panel Mode Switch

For more details on the operator panel see

Section A.3, “Operator Panel

Overview” on page A-9

.

4. Turn on the input power.

Note –

Wait at least 30 seconds before turning on the system power that you turned

off, by pulling out the power cord or using the circuit breakers on the distribution
panel.

Refer to the manual that shipped with the input power source for instructions.

5. Watch the administration console for error messages as the XSCF Unit powers

on.

See

Appendix B

for fault installation information.

6. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.

Note –

Step 8 must be performed within a minute of Step 7 or the login certification

will time out.

7. When the login prompt appears, enter default for the login name:

8. Set the key on the operator panel to the Locked position.

9. Press the RETURN key.

Wait five seconds before continuing to Step 10.

10. Set the key on the operator panel to the Service position and press the RETURN

key.

login: default