SPARC Enterprise M4000/M5000 Servers Installation Guide • December 2010

Note –

setdualpowerfeed

requires a complete chassis power cycle (all power

cords removed) to apply any changes. Make certain to allow 30 seconds before
plugging the power cords back into the chassis.

To perform XSCF initial settings, use the XSCF default user account. Until user
accounts for user environment is registered, log in with a default user account and
default password. The privileges of the default user are useradm and platadm.

2. Log in to the XSCF Shell using a user account and password set during Step 1.

See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s
Guide
for details on how to log in to the user account.

3.4

Powering On the Server

This section explains how to power on the server the first time.

1. Set the key on the operator panel to the Service position.

2. From the XSCF Shell, type the console command:

3. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.

4. Push the power switch on the operator panel to power on the server.

The server starts and begins a self-diagnosis.

Watch the initial system administration console for error messages during the boot
process. See

Appendix B

for fault installation information.

5. Confirm that “ok” is displayed on the domain console.

XSCF> console -d 0