B.2.3

Using the showstatus Command

The showstatus displays the information concerning the server’s degraded FRUs.
An asterisk (*) which indicates that the unit has been degraded is displayed along
with any of the following states:

Normal

Faulted

Degraded

Deconfigured

Maintenance

An example of the showstatus output.

B.2.4

Using the fmdump Command

The fmdump command can be used to display the contents of any log files associated
with the Oracle Solaris fault manager.

This example assumes there is only one fault.

B.2.4.1

fmdump -V

Command

You can obtain more detail by using the -V option, as shown in the following
example.

XSCF> showstatus

FANBP_C Status:Normal;

* FAN_A#0 Status:Faulted;

XSCF>

# fmdump

TIME UUID SUNW-MSG-ID

Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y

# fmdump -V -u 0ee65618-2218-4997-c0dc-b5c410ed8ec2

TIME UUID SUNW-MSG-ID

Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2

SUN4-8000-0Y

100% fault.io.fire.asic

FRU: hc://product-id=SUNW,A70/motherboard=0

rsrc: hc:///motherboard=0/hostbridge=0/pciexrc=0