Replacement of parts – Garland STW286A User Manual

Page 18

Advertising
background image

Part # 4517957 Rev. 13 (02/10/11)

Page 18

WARNING: Turn off the gas supply to the appliance at the

service cock and the electrical mains before commencing

any servicing work.

IMPORTANT: Test for gas leakage on completion of any

servicing work.

Gas Taps

1. Pull the knob off of each gas tap and thermostat on the

unit.

2. Remove the screws securing the fascia panel and remove

panel and grease drawer.

3. Remove the appropriate burner (if necessary) following

the procedure given in the section on Main Burner

Cleaning.

4. Disconnect the thermocouple connection at the gas tap.

5. Disconnect the pilot and main burner tubing connections

at the gas tap.

6. Disconnect the tubing connection at the inlet of the gas

tap and remove the tap.

7. Replace with the new tap.

8. Reassemble in the reverse order.

Door Switch

1. Remove the lower kick panel.

2. Disconnect the wires from the terminals on the body of

the switch.

3. Remove the screws securing the door switch to the

mounting bracket and remove the door switch.

4. Replace the faulty door switch.

5. Make certain that the newly installed door switch is

properly adjusted so as to interrupt the power supply

to the gas control system and fan motor when the oven

doors are opened.

Control Panel Rocker Switches

1. Remove the fastener securing the control compartment

access panel.

2. Slide out the control drawer to access the switch.

REPLACEMENT OF PARTS

3. Disconnect the wires from the taps on the switch. Be sure

to note which wire connects to which terminal on the

switch.

4. Depress the tabs of the switch body and push the switch

through the opening in the control panel.

5. Replace the switch and reassemble in the reverse order.

Thermostat

1. Remove the fastener securing the control compartment

access panel.

2. Slide out the control drawer to access the thermostat.

3. Remove the dial from the thermostat and the screws

securing the thermostat body to the control panel.

4. Remove the wires from the thermostat terminals. Be sure

to note which wire connects to which terminal on the

thermostat.

5. Remove the thermostat sense bulb.

6. Replace the faulty thermostat and reassemble in the

reverse order.

Heat-On Lamp

1. Remove the fastener securing the control compartment

access panel.

2. Slide out the control drawer to access the lamp.

3. Disconnect the supply wires to the lamp body and

remove the faulty lamp.

4. Reassemble in the reverse order.

Gas Control Valve

1. Remove the fastener securing the control compartment

access panel.

2. Slide out the control drawer.

3. Remove the main body side panel to access the gas train.

4. Break the pipe union connection at the inlet of the gas

control and the 7/16” union connection located at the

outlet of the control.

5. Remove the wires from the connections to the gas valve.

Be sure to note which wires connect to which terminal

before doing so.

Advertising