Installation continued, Commissioning, Burner adjustments: griddle /solid hot top burner – Garland STW286A User Manual

Page 9: Hot top minimum flame setting, Oven burner

Advertising
background image

Part # 4517957 Rev.13 (02/10/11)

Page 9

INSTALLATION continued

Commissioning:

The whole of the gas installation, including the meter, should

be inspected, purged and tested for leakage in accordance

with local codes.

1. Ensure that all controls are in the off position and turn on

the main gas supply and electrical mains.

2. Remove the screws securing the front fascia and connect

a U-gauge manometer to the pressure test point on the

main manifold. Operate the main burners in accordance

with the instructions given in the User’s manual.

3. Check that the setting pressure is correct per TABLE C

on the previous page. If necessary, adjust the pressure

governor located at the rear of the range, downstream of

the shut-off valve, to give the required setting.

Burner Adjustments:
Griddle /Solid Hot Top Burner

Check that the aeration shutter is set to provide the

required opening per table E on the previous page. Adjust if

necessary.

FIXING SCREW

SHUTTER

OPENING

MEASUREMENT

INJECTOR

LOCATION

Hot Top Minimum Flame Setting

1. Set the gas tap to the MIN position.

2. Connect a U-gauge manometer to the pressure test

nipple located downstream of the gas tap.

3. With a flat screwdriver, turn the adjuster on the body of

the tap clockwise to reduce the pressure or anti-clockwise

to increase pressure. Set the pressure to correspond with

table D.

PILOT

ADJUSTER

LOW FLAME

ADJUSTER

TEST POINT

Oven Burner

1. Check that the aeration shutter is set to the required

opening per table E. Adjust if necessary.

SHUTTER

OPENING

MEASUREMENT

When all the settings have been checked, remove the U-

gauge manometer, replace the pressure test point screw and

the lower front panel.

Instruct the user or purchaser in the efficient and safe

operation of the appliance.

Tell the user of the location of the gas isolation cock for use

in an emergency. Leave this User Installation and Servicing

Instruction Manual with the user or purchaser.