NOTE: For Wall Control, wire and insulated

staples locate Bags 6 and 7 from Box 2.

1. Wall Control location.

• Wall Control location should be in direct sight

of door.

• It should be at least five feet (5') above floor to

prevent small children from operating door.

• It must be away from any moving parts. (You

should NOT be able to reach the garage door

while standing at Wall Control.)

• Wall Control board screw connections are

polarized, (+) positive and (-) negative.

2a. Wiring (If pre-wired).

• Locate Wall Control pre-wired wire ends

(Fig. 3-1). (They should be located within the

guidelines mentioned above.)

• Split and strip ends of wire

(Fig. 3-2).

• Fasten wire to Wall Control board screws on

back of Wall Control.

– Striped wire to the + (plus) terminal.

– White wire to the - (minus) terminal.

2b. Wiring (If NOT pre-wired).

• Pick a convenient location for mounting

Wall Control using the guidelines mentioned

above

(Fig. 3-1).

• Run wire from power head to Wall Control

(Fig. 3-1).

• Split and strip ends of wire

(Fig. 3-2).

• Fasten wire to Wall Control board screws on

back of Wall Control.

– Striped wire to the + (plus) terminal.

– White wire to the - (minus) terminal.

WALL CONTROL INSTALLATION

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

3

Verify there is

NO power to the opener before

installing Wall Control wires and Wall Control.

WARNING

Staples which are too tight can cut or pinch wires.

Cut or pinched wires can cause the Wall Control to

stop working. When using the insulated staples,

make sure you fasten them only as tightly as

needed to hold the wire snugly.

CAUTION

FIG. 3-2 Splitting and stripping

.

FIG. 3-1 Wall Control wire routing

Wire from

power head

to Wall Control

Wall

Control

"Entrapment"

warning label

Separate

entry door

EXAMPLE ONLY!

This is an example of wire routing

when NOT pre-wired. Your wire

routing may be different.

1/2"

2"

15

Black
Striped

White

+

or

or

Use of any other wall control can cause the door to

operate unexpectedly and the light not to work.

Use only the included Wall Control.