Troubleshooting guide – Genie 2024 User Manual

Page 27

Advertising
background image

PN# 37026500123 05/15/2009

27

TROUBLESHOOTING GUIDE -

OPERATION

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

PROBLEM

WHAT TO DO

Opener does NOT run

from Wall Control.

• Check power source.

– Plug a lamp into outlet used for power head. If lamp works, power source is OK.

– If not, check fuse or circuit breaker.

• If power is OK.

– Check connections at power head terminals and at Wall Control.

• Check for reversed, broken, or cut wires. Staples can cut insulation and short wires. Repair or

replace.

Opener runs, but door

does NOT move.

• Make sure carriage is engaged to carriage slide.

– Place carriage lever in lock position.

• Check to make sure chain/belt is not broken or OFF its track.

• Check FORCE ADJUSTMENT (See section ). Door opener will NOT run more

than 30 seconds each way if door does not move.

6

Opener works from Wall

Control, but NOT from

remote control.

• Confirm vacation lock switch on wall control is OFF. (See section ).

• Program remote control code into receiver memory (See section ).

• Replace remote control battery (See section ).

3

8

7

Remote control has

less than 25 feet

operating range or no

operation.

• Relocate remote control inside car and or point remote control at garage door.

• Replace battery (See section ).

• Reposition door opener antenna.

• Red LED blinks while button is being pushed or LED does not come ON - battery is

low, replace battery.

8

Door starts down, then

STOPS and goes back

up.

OR

Safe-T-Beam

®

System

malfunction.

• If a NEW installation, check Door Arm position

, (See section ).

• Check if Safe-T-Beam

®

Red LED is flashing.

• Check Safe-T-Beam

®

system for beam obstruction or misalignment of lenses.

Realign or replace Sensors. (See section )

• Check "CLOSE FORCE" adjustment (See section ).

• Check garage door for binding.

• If an operational problem exists, and opener will not run closed. The opener can be

forced to close as follows (See section ). Hold the wall control button down until

door is completely closed.

• Disconnect the Safe-T-Beam

®

System from the opener and contact an authorized

Genie

®

Dealer or The Genie Company at 1-800-35-GENIE.

5

6

3

2

Door starts down, then

STOPS before it is

closed.
OR
Door will only open.

• Check CONTACT REVERSE (See section ).

• Check garage door for binding.

• Wires shorted. Staples can cut insulation and short wires. Repair or replace.

• Check "CLOSE FORCE" adjustment (See section ).

6

6

Door starts up, but

STOPS before it’s

completely open.

• Be sure door, opener, and springs are in good repair, properly lubricated and

balanced (See Maintenance section ).

• Check "OPEN" limit setting (See section ).

• Check "OPEN FORCE" adjustment (See section ).

WARNING: If you suspect a problem with the garage door hardware or springs, contact

an authorized Genie

®

Dealer or a trained door system technician, or contact The Genie

Company at 1-800-35-GENIE.

10

6

6

Door will only run in

close direction.

• Check door balance, condition, and door spring.

• Check "OPEN FORCE" adjustment (See section ).

WARNING: If you suspect a problem with the garage door hardware or springs, contact

an authorized Genie

®

Dealer or a trained door system technician, or contact The Genie

Company at 1-800-35-GENIE.

6

Door opener starts for

no reason.

• Was a remote control lost or stolen? Erase all remote control codes from receiver

memory and reprogram (See section ).

• Button stuck on Wall Control or remote.

• Check CLOSE limit switch setting (See section ).

• Wires shorted. Staples can cut insulation and short wires. Repair or replace.

6

7

Noisy operation.

• Be sure all fasteners are tight.

• Be sure door and opener are in good repair, properly lubricated and balanced (See

Maintenance section ).

10

Advertising