Multi-Tech Systems MT2834BLR User Manual

Page 14

Advertising
background image

14

Chapter 2 - Installation

Dip Switch Settings #13 - 16

Note:

A modem baud rate command (e.g., $MB33600) overrides the

setting of the speed selection switches (#13 and #14).

Switch Position

Effect

13/14

UP/UP*

28.8 K bps Operation (Default)

13/14

DOWN/UP

19.2 K bps Operation

13/14

UP/DOWN

14.4 K bps Operation

13/14

DOWN/DOWN

9600 bps Operation

#15

UP*

CD/DSR from Interface

#15

DOWN

CD/DSR Forced On

#16

UP

Used in combination with

#16

DOWN

DIP-Switch #9/Loopback Tests

* Factory default setting

2.4

OOS (Busy Out) Toggle Switch

The MT2834 contains a two-position OOS switch on the front panel. This
switch can be used to create a “busy out” (OOS) condition for the modem
(i.e., take the modem off-hook). To place a modem in the Busy condition,
move the OOS toggle switch to the (BUSY) position. The modem then
goes off-hook, its OOS and OH LEDs light, and incoming calls to this
modem get a busy signal. If you suspect a problem with a particular
modem, you can use the BUSY switch to have an optional device (such as
a “hunt group”) that looks for a non-busy line to perform a “roll over” to the
next available modem while you check the status of the Busy modem.