Chapter 4 - commands – Multi-Tech Systems MT2834BLR User Manual

Page 51

Advertising
background image

51

Chapter 4 - Commands

S25
DTR Dropout Time

Unit:

100 mSec.

Range:

0, 1 through 255

Default:

0

Description:

Defines DTR dropout time. 0 default equals 50ms.

S26
Failed Password Attempts

Unit:

1 failed attempt

Range:

0-255

Default:

0

Description:

Counts the number of times there has been a failed
password attempt.

S29
Local Inactivity Timer

Unit:

minutes

Range:

1-255

Default:

20

Description:

Defines the amount of idle time that can elapse between
AT commands after the SETUP password has been
entered.

S30
Inactivity Timer

Unit:

1 minute

Range:

0-255

Default:

0

Description:

Inactivity timer used to disconnect the modem.

S32
Time Elapse for Escape Sequence

Unit:

1 second

Range:

0-255

Default:

20

Description:

Sets the duration in which modem waits for a <CR> to be
entered during escape sequence execution.

S34
Buffer Length of Command Mode...After On-line Escape Sequence

Unit:

ASCII Character

Range:

0-60

Default:

10

Description:

Sets buffer length of command mode after on-line escape
sequence.