Multi-Tech Systems MT2834BLR User Manual

Page 61

Advertising
background image

61

Chapter 5 - Testing the Modem

5.4

Local Analog Loopback Test (Synchronous Mode)

To initiate the Local Analog Loopback Test, with the modem in
Synchronous mode:

1. Enter AT&M1U. This first switches your modem from asynchronous to

synchronous mode, and places it into the Analog Loopback/Originate
mode. The modem is now out of the Command mode and in the
pseudo On-Line mode.

2. Once you receive a connect message (if responses are enabled), enter

data from your keyboard. For this test, typing multiple upper case "U"
characters is a good way to send an alternating test pattern of ones and
zeros.

3. For a more complete test, you should also test the modem in Answer

mode. To do this, pull out and then reinsert modem card in rack cage.
Then type AT&M1U1 and hit ENTER to place the modem in Analog
Loopback mode, in the Answer mode. Then repeat step 2.

Figure 5-4. Local Analog Loopback Test (Syncronous Mode)