Chapter 4 - Commands

VALUES:

n = 0 thru 2

DEFAULT:

#F2

DESCRIPTION:

#F0 means no fallback when on-line.
#F1 means fallback from 33600 to 4800 bps when on-line
(increments of 2400 bps).
#F2 means fallback to 4800 bps from 33.6K bps/fall
forward if line improves (increments of 2400 bps).

COMMAND:

&Fn

VALUES:

n = 0, 8 or 9

DEFAULT:

&F8

DESCRIPTION:

&F loads factory default values from ROM.
&F8 reads factory default values when &F is issued.
&F9 reads parameters stored in nonvolatile memory when
&F is issued.

COMMAND:

$Fn

VALUES:

n = 0 or 1

DEFAULT:

$F1

DESCRIPTION:

$F0 means do not fall back to normal connect if CR
received.
$F1 means fall back to normal connect if CR received.

COMMAND:

$FCn

VALUES:

n = 0 or 1

DEFAULT:

$FC1

DESCRIPTION:

$FC0 means no transmit of 5 second 2100Hz signal.
$FC1 transmits 5 second 2100Hz signal.

COMMAND:

&Gn

VALUES:

n = 0, 1 or 2

DEFAULT:

&G0

DESCRIPTION:

&G0 turns off CCITT guard tones.
&G1 turns on CCITT 550 Hz guard tone.
&G2 turns on CCITT 1800 Hz guard tone (not used on
International models).

COMMAND:

Hn

VALUES:

n = 0 or 1

DEFAULT:

n/a

DESCRIPTION:

H0 selects Hang Up (go on hook).
H1 selects Go Off Hook.

COMMAND:

$Hn