Chapter 4 - commands – Multi-Tech Systems MT2834BLR User Manual

Page 50

Advertising
background image

50

Chapter 4 - Commands

S10
Carrier Loss Disconnect Delay Time

Unit:

100 mSec.

Range:

0-255

Default:

7

Description:

Sets the time a carrier signal must be lost before the
modem disconnects.

S11
Tone Dialing: Tone Spacing and Duration

Unit:

1 mSec.

Range:

1-255, 80-255*

Default:

70, 80*

Description:

Sets the time duration of spacing between tone in tone-
dialing.

S13
Remote Configuration Escape Character

Unit:

ASCII Character

Range:

0-127

Default:

37 (% sign)

Description:

Defines the remote configuration escape character.

S16
Callback Attempts

Unit:

1 Attempt

Range:

1-255

Default:

4

Description:

S16 defines the number of attempts allowed after initial
passwords have been exchanged between modems.

S17
Changing Break Time

Unit:

10 mSec.

Range:

0-2.5 sec

Default:

250

Description:

S17 defines the break time (space) to local PC.

S24
PBX/CBX Disconnect Drop Time for DSR/CTS/CD

Unit:

50 mSec.

Range:

0-255

Default:

20

Description:

Defines DSR/CTS/CD dropout time. The default of 20
equals one second.

Advertising