Scan resume condition, Scan operation – Icom IC-U82 User Manual

Page 45

Advertising
background image

33

8

SCAN OPERATION

8

D

Memory scan watch

While operating on a VFO frequency, memory scan watch
monitors for signals in each memory channel in sequence,
every 5 sec.

q Push

[C•

MR

]

to select memory mode, if necessary.

• “X” appears.

w Push

[A•

FUNC

]

, then push

[5•

SCAN

]

to start the memory

scan.

e Push

[A•

FUNC

]

, then push

[7•

PRIO

]

to start the watching.

• VFO is displayed, then the decimal point “

.

”, on the frequency

readout blinks.

• When the signal is detected on the priority channel, the watching

is suspended according to the setting of the scan resume condi-
tion.

r Push

[D•

CLR

]

to stop the watching.

Scan resume condition

When a signal is received during scanning, the scan resume
condition determines what action the transceiver takes. The
transceiver has 2 scan resume conditions available as
illustrated below. Use

SET MODE

to select the one which best

suits your needs.

q Push

[A•

FUNC

]

, then push

[8•

SET

]

to enter

SET MODE

.

w Push

[

Y

Y

]

or

[

Z

Z

]

several times until “SCP” or “SCt” ap-

pears.

e Rotate

[VOL]

to select the desired scan resume condition.

Pause scan:

When receiving a signal, scan pauses on
the signal until it disappears. Resumes
2 sec. after the signal disappears.

Timer scan:

When receiving a signal, scan pauses on
the signal for 5 sec., 10 sec. or 15 sec.,
then resumes.

r Push

[

ENT

]

(or

[D•

CLR

]

) to set and exit

SET MODE

.

Timer scan

Pause scan

USING

SET MODE

SKIP

Mch 1

Mch 2

Mch 3

Mch 4

Mch 5

Mch 199

Mch 6

Priority channel

Memory
scan

5 sec.

50 msec.

VFO frequency

Advertising