Sun Microsystems StorEdge 6900 Series User Manual

Page 112

Advertising
background image

96

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002

TABLE 7-5

lists the Virtualization Engine Events.

TABLE 7-5

Storage Automated Diagnostic Environment Event Grid for Virtualization Engine

Category

Component

EventType

Sev

Action

Description

virtualization
engine

enclosure

Alarm

Yellow

Volume E00012 on
v1a changed
mapping.

virtualization
engine

enclosure

Alarm.log

Yellow

Change in Port
Statistics on
virtualization
engine v1a

virtualization
engine

enclosure

Audit

[ Info ] Auditing a
Virtualization
Engine called v1a

Information:
Audits occur every
week and send a
detailed description of
the enclosure to the
Sun Network Storage
Command Center
(NSCC)

virtualization
engine

oob

Comm_

Established

Communication
regained with
virtualization
engine v1a

virtualization
engine

oob

Comm_
Lost

Down

Y

[ Info/Action ]
Lost
communication
with virtualization
engine v1a

Information:
Ethernet connectivity
to the virtualization
engine unit has been
lost.

Recommended action:
1. Check Ethernet

connectivity to the
virtualization
engine.

2. Make sure the

virtualization
engine is boosted
correctly.

3. Verify that the

TCP/IP settings on
the virtualization
engine are correct.

4. Replace the

virtualization
engine if necessary.

Advertising