Sun Microsystems StorEdge 6900 Series User Manual

Page 72

Advertising
background image

56

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

host

lun.VE

Alarm-

Red

Y

[ Info ] The state of

lun.VE.c14t50020

F2300003EE5d0s2.

statusA on

diag.

xxxxx.xxx

.com

changed from OK to
ERROR
(target=ve:diag244-
ve0/90.0.0.40)

luxadm

display

reported a change in
the port status of
one of its paths. The
Storage Automated
Diagnostic
Environment then
tries to find to
which enclosure this
path corresponds by
reviewing its
database of Sun
StorEdge T3+ arrays
and virtualization
engines.

host

ifptest

Diagnostic
Test-

Red

Y

ifptest (diag240) on
host failed.

host

qlctest

Diagnostic
Test-

Red

qlctest (diag240) on

host failed.

host

socaltest

Diagnostic
Test-

Red

socaltest (diag240) on
host failed.

host

enclosure

PatchInfo

[ Info ] New patch

and package
information
generated.

Send changes to the
output of showrev -
p and

pkginfo -|

.

host

enclosure

backup

[ Info ] Agent Backup

Backup of the
configuration file of
the agent.

TABLE 5-1

Storage Automated Diagnostic Environment Event Grid for the Host (Continued)

Advertising