For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 83

Advertising
background image

Chapter 6

Troubleshooting Sun StorEdge FC Switch-8 and Switch-16 Devices

67

For Internal Use Only

switch

port

StateChange+

[ Info/Action ] port.1

in

SWITCH diag185

(

ip=

xxx.20.67.185

) is

now Available (status-
state changed from
OFFLINE to ONLINE)

Port on switch is
now available.

switch

port

StateChange-

Red

Y

[ Info/Action ] port.1

in

SWITCH diag185

(

ip=

xxx

.20.67.185

)

is now Not-Available
(status state changed
from ONLINE to
OFFLINE)

Information: A port
on the switch has
logged out of the
Fabric and has gone
offline.

Recommended
action:
1. Verify cables,

GBICs, and
connections
along the Fibre
Channel path.

2. Check Storage

Automated
Diagnostic
Environment
SAN Topology
GUI to identify
failing segment
of the data path.

3. Verify the correct

FC switch
configuration.

switch

enclosure

Statistics

[ Info ] Statistics

about

switch d2-

swb1

(ipxxx.0.0.41)

10002000007a609

Port Statistics

TABLE 6-1

Storage Automated Diagnostic Environment Event Grid for Switches (Continued)