Sun Microsystems StorEdge 6900 Series User Manual

Page 149

Advertising
background image

Appendix B

SUNWsecfg Error Messages

133

Common to
virtualization engine

1. Device-side operating mode is not

set properly.

2. Device-side UID reporting scheme

is not set properly.

3. Host-side operating mode is not set

properly.

4. Host-side LUN mapping mode is

not set properly.

5. Host-side Command Queue Depth

is not set properly.

6. Host-side UID distinguish is not set

properly.

7. IP is not set properly.
8. Subnet mask is not set properly.
9. Default gateway is not set properly.
10. Server port number is not set

properly.

11. Host WWN Authentications are not

set properly.

12. Host IP Authentications are not set

properly.

13. Other VEHOST IP is not set

properly.

Log in to the virtualization engine and
verify that the device, host, and
network settings are correct. Make sure
the virtualization engine hardware is
not in ERROR 50 mode. If required,
power cycle the virtualization engine
hardware, or disable the host-side
switch port. Run the

setupve -n

ve_name

command and enable the

switch port.

checkslicd

Cannot establish communication with

${vepair}

.

Run

startslicd -n ${vepair}

.

checkslicd

Cannot establish communication with
virtualization engine pair

${vepair}

initiator

{$initiator}

.

Determine the host name associated
with

${initiator}

by using the

showvemap -n ${vepair} -f

command output. Run the command
r

esetve -n vename

.

checkvemap

Cannot establish communication with

${vepair}

Run the command again. If this fails,
check the status of both virtualization
engines. If there is an error condition,
see Appendix A for corrective action.

TABLE B-1

Virtualization Engine SUNWsecfg Error Messages (Continued)

Message

Description and Cause of Error

Suggested Action

Advertising
This manual is related to the following products: