36

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

FIGURE 3-7

A3/B3 FC Link Storage Service Processor-Side Event

FIGURE 3-8

A3/B3 FC Link Storage Service Processor-Side Event

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : Switch Key: switch:100000c0dd0057bd

EventType: StateChangeEvent.M.port.1

EventTime: 01/08/2002 18:28:38

’port.1’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Not-Available

(status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline

Action:

1. Verify cables, GBICs and connections along Fibre Channel path

2. Check Storage Automated Diagnostic Environment SAN Topology GUI to

identify failing segment of the data path

3. Verify correct FC switch configuration

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : Switch Key: switch:100000c0dd00cbfe

EventType: StateChangeEvent.M.port.1

EventTime: 01/08/2002 18:28:40

’port.1’ in SWITCH diag-sw2a (ip=192.168.0.32) is now Not-Available

(status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline

Action:

1. Verify cables, GBICs and connections along Fibre Channel path

2. Check Storage Automated Diagnostic Environment SAN Topology GUI to

identify failing segment of the data path

3. Verify correct FC switch configuration